· Electrode manufacturing
Modelling the Electrode Calendering U-Shape
Updated 11 November 2026, including preprint references published after the original post.
Lithium-ion cells depend on calendered electrodes for volumetric energy density. Predicting what compression does to through-plane thermal conductivity (λeff) turns out to be harder than it looks. On first thought, a monotone relationship is expected: press harder, conductivity should rise.
The measured conductivity can first fall and then recover during calendering. A porosity-only or static-contact closure misses that U-shape. Two plausible contributions are changing contact networks and, for graphite, particle reorientation. The thermal curve alone does not determine their individual shares. For quasi-isotropic NMC, a contact term that first weakens and then recovers can reproduce the U without a graphite-like orientation mechanism.
Particle reorientation as a graphite hypothesis
The missing mechanism is graphite anisotropy. Conductivity within the graphene planes is high; perpendicular to them it is poor, by more than an order of magnitude. Compression brings particles closer, but it also rotates them, laying the flakes flat against the current collector.
Flat flakes present their poor through-plane axis to the direction heat must travel. Early calendering therefore trades a shrinking pore volume for a worsening particle orientation, if the orientation loss outweighs contact growth. Once most flakes are already aligned, further reorientation contributes less. At that point, growing particle-particle contact starts to dominate and the curve turns upward.
The fitted closure adds a compression-dependent contact term φ(Π) to a Knudsen-corrected Zehner–Bauer–Schlünder base. Its in-sample MAPE falls from 31.1% to 4.5% over 27 states in four electrode families. A separate, bounded reorientation account is compared for graphite; it is not independently identified by this contact-term ablation.
The 4.5% MAPE is in-sample across 27 states from four electrode families: thin and thick graphite anodes and thin and thick NMC cathodes. They come from one public dataset and one metrology chain. The draft reports 7.8% leave-one-state-out error. That checks interpolation within these families, while transfer to new recipes and measurement methods needs separate evidence.
Table 3 compares M0, the zero-fit ZBS reference; M1, a fitted constant contact fraction; and M2, a process-dependent contact term φ(Π). This ablation measures the benefit of the contact model. It does not isolate reorientation, because M2 adds contact evolution rather than an independently measured texture contribution.
A U-shaped response requires some contribution to turn downward or competing contributions to exchange dominance. It does not require both porosity and reorientation: a non-monotone contact network can be sufficient, as in the NMC fit. For graphite, same-sheet texture measurements alongside thermal and contact measurements would distinguish reorientation from contact damage and recovery.
Use your identity on another device
Save an encrypted identity file and restore it in another browser. Keep the file and its passphrase private.